However, perhaps the most crucial check is to test the integrity of the fusible link. Fire dampers are hidden from building occupants and generally from the owner and operational team, however they play an essential role in fire and smoke protection. Hse information sheet testing regime for offshore trhvac. All dampers are asset tagged, photographed, cleaned and drop tested and detailed in a full report utilising our bespoke software package. Round fire damper allows the fusible link to be replaced easily then the damper can be adjusted to its fullopen position. Also mark the location of the fire and smoke dampers and its corresponding number on the facilitys drawings.
Then, each fire damper must be tested and inspected one year after the installation. In other words, the integrated systems include many of the systems located in buildings today, such as fire alarm and detection systems, firesuppression systems, smokecontrol systems, emergency. This service was performed under the present nfpa90a requirement for a 4 year frequency. Verify that required maintenance duties are completed, so that fire dampers are working properly. Halton fdi fire damper installation video duration. On each side of the stage there is a box market in case of fire break glass push button, for fire damper operation. Y satisfactory n unsatisfactory na not applicable damper number or location damper type tested fully closed latch checked fusible link removed moving parts. Guide for facility managers on the testing and maintenance of fire. Attachment of retaining angles must not restrict operation of the fire damper. Set dampers to fully open position before testing, adjusting, and balancing.
A fire damper can be defined as a device installed in ducts and air transfer. The fire damper testing will include many different things such as locating and operating all fire dampers and smoke dampers in the facility, removing and resetting the fusible link, to verify the damper fully closes. Install fire and smoke dampers according to the manufacturers ul listing. As dampers are metal curtains that shut when heat or fire causes the fusible link to melt, it is vital that this aspect of the damper is fully functional.
Fire damper testing ruskin authority in air control. Fire damper testing and maintenance duct cleaning specialists. Fire damper inspections and testing ductwork can transfer flame and smoke at a drastic speed through a building when a fire occurs. Integral or standalone controls are functionally tested with the equipment they are attached to, including any interlocks with other equipment or systems and thus are not covered under the bas testing. Testing and inspection requirements for fire dampers. An operational test must be completed once the fire damper is installed. Hvac dampers installation method statement method statement hq. Where the fire damper sleeve is exposed to the airstream, the metal sleeve will be of the same material as the duct system. The hazard from failure of hvac fire dampers to close on demand is defined as a loss of tr habitat via gassmoke ingress etc. Interface fire and smoke damper with the fire alarm system. A fire damper is a device installed in ducts and air transfer openings of an air. Drop testing the fire damper to ensure its correct functionality. Fire damper testing quality environmental services.
Typically smoke dampers are designed to prevent the flow of smoke and products of combustion and are able to withstand high differential pressures. After you hit the one year mark, your fire dampers must then be tested and inspected every four yearsexcept for hospitals, which have a sixyear frequency. Fido fire damper openers help make this process safer and easier, while also saving significant time and money. Remote fire and smokedamper testing nears hpac engineering.
For more information about the dampers seen in these tests, please check the following links. Jun 21, 2010 fire damper testing ruskin authority in air control. Fire damper maintenance legislation ductbusters uk. As with testing dynamic fire dampers, testing a smoke damper should be done under normal airflow conditions to confirm no impediment to operation exists due to rust or damaged blades. The important point is that ticking a box to say that a fire damper exists is not compliance that will stand up in case of a problem. My facility has in house sprinkler, extinguisher, fire door, fire pump, fire alarm, etc testing that at the moment we print off our reports on microsoft word document and bring with us then come back to the office to manually enter the changes. This could be years after their installation and initial testing.
The build up of heat inside the duct can cause any flammable material near the ductwork, such as roof joists, to burst into flames. Resetting fire dampers by hand after a test has been performed can be an unsafe, difficult, and timeconsuming process. Periodic testing of fire and smoke dampers and associated controls is. The fusible links used to close fire dampers are ul listed.
Each fire damper must be tested and inspected one year after the installation. Vdo demonstrates function of the fire damper, model. Verify proper operation through testing measures used in this app that ensure compliance with safety requirements. Fire, smoke, and combination damper inspection, testing and. Any modifications or repairs made are described below. A movable closure within a duct which is operated automatically or manually and is designed to prevent the passage of fire regular maintenance fire dampers should be inspected annually as a minimum for correct function and condition in line with the regulatory reform fire safety order 2005 and. The essential test is that the damper will open and close and no obstructions are present. They either have a link that melts in high heat, causing the damper to close or are alerted to the presence of a fire by an electric signal from the buildings fire alarm system. Ruskin ceiling fire radiation damper webinar duration. We just completed our fire smoke damper inspection and testing program for 2004. These are often subject to sudden direct flame impingement. The close and open manual switches can be used to override the damper. Testing and maintenance of fire dampers, especially dynamic.
Intumescent fire dampers are required to comply with the air leakage requirements detailed in this standard and are tested up to a pressure of 1250pa. Verify proper operation through testing measures used in this. Fido2 fido2 fire damper opener fire damper openers. We just completed our firesmoke damper inspection and testing program for 2004. This memorandum permits hospitals to apply the nfpa 6year testing interval for fire and smoke dampers in hospital heating and ventilating systems, so long as the hospitals testing system conforms to the testing requirements under the 2007 edition of nfpa 80 and nfpa 105. Nfpa 72 fire alarm inspection and testing requirements 1. Mar 22, 20 first, an operational test must be completed after the installation of the fire damper is complete.
It shall be permitted to modify this form as needed to provide a more complete andor clear record. After you hit the one year mark, your fire dampers must then be tested and inspected every four yearsexcept for hospitals, which have a sixyear. Code required for testing of fire, smoke, and combination. Fire and smoke damper testing and inspection explained. This is to certify that the following testing and maintenance was performed on the dampers listed. The joint commission tjc as well as local authorities having jurisdiction ahj require that healthcare facilities perform periodic inspections of fire, smoke and combination dampers for proper function and operability. Guide for facility managers on the testing and maintenance. By providing a barrier beyond which the fire cannot pass, effective fire dampers save lives. A facility managers guide to testing and maintaining fire dampers.
After determination of the repairs necessary, performance testing must be performed. Center for medicaid and state operationssurvey and. Bs 9999 fire damper maintenance legislation the bs 9999 legislation on fire damper maintenance states that all fire dampers must be tested by a competed person after they have been installed and. Use this fire damper inspection report tool to promote life safety through proper operation of dampers. How to properly inspect and test fire dampers facilities. For healthcare occupancies, the damper inspectiontesting requirement has been. Ruskins classic inspector consists of a panel pc, ups and preloaded software. Damper test software benefits from over 30 years experience in damper testing.
The following requirements are from the 2009 edition of the standard. This must be removed and the fire damper tested regularly to ensure that it. Ventilating cavity fire barriers is a type of air transfer fire damper used in cavities or voids in constructions with natural ventilation, typically inside air gaps behind cladding. Note that this discussion applies only to fire dampers and combination fire smoke dampers. Provide test holes at inlet and outlet and elsewhere as indicated. Basic training fire and smoke damper actuator replacement rev 1.
It encompasses everything from simple characterisation and assurance, to the development of the latest active and electrorheological dampers. Is there a program out there being used by a contractor or in house inspector like myself that we. Required smoke barrier partitions shall be maintained to prevent passage of smoke and all openings protected with approved smoke barrier doors or leakagerated smoke dampers. Healthcare fire and smoke damper inspection and testing tips. Basic training fire and smoke damper actuator replacement. Chapter 6 installation testing, and maintenance of smoke damper is. Freeman air experts has been providing commercial and residential fire and smoke damper inspection and air duct cleaning services throughout the united states for the past 20 years. The following is a brief summary of the code requirements pertaining to fire and smoke fs dampers. Code required for testing of fire, smoke, and combination dampers. First, an operational test must be completed after the installation of the fire damper is complete. An additional solution for round ducts is the use of a true round fire damper.
The operation must be under the airflow conditions that the system will encounter. Regularly testing and maintaining your fire dampers can save lives. Install access doors with swing against duct static pressure. As long as the fire damper is installed at right angles to the ductwork, without obstructions in the track, the damper will close. Fire damper inspection report form mobile app iphone, ipad. Fire damper inspections and testing air and fire ltd. Fire damper inspection archives life safety services. Faq friday, nfpa 80 what is the inspection and testing. Guide for facility managers on the testing and maintenance of. Maintenance to verify the continued operation of the fire damper is up to the property owner to perform on a regular basis.
Lss life safety services lss can provide fire and smoke damper inspections per code requirements and assist you in keeping your facility in compliance with local and state building codes. It is not intended to address smoke dampers which are used for smoke managementcontrol only and are not used as fire separation protection. Ahjs are requiring operational tests to determine if the damper will function. Information on this website is available in alternative formats upon request. Typec dampers and typec sleeved dampers are the only dampers that can be built as mediumhigh or high.
Note that this discussion applies only to fire dampers and combination firesmoke dampers. Fire, smoke, and combination damper inspection, testing and maintenance requirements. The metal fab fire damper pressure rating as it relates to manufacturing the damper. Use our fire damper testing and inspection to make sure that yours are always up to. Uncompleted equipment functional tests or outstanding deficiencies in those tests lend the required bas functional testing incomplete. Testing and maintenance of fire dampers, especially dynamic, curtain fire dampers, can be extremely difficult. Certain ul approved designs do not require retaining angles. Functional test of 10% of the system including a test of at least one device per inputoutput circuit verify critical functions including notification. This standard specifies the requirements for the materials, manufacture, performance, testing and marking of fire dampers. Intumescent fire dampers kilargo the right choice for the. Astm e2912 17 standard test method for fire test of non. The joint commission tjc as well as local authorities having jurisdiction ahj require that healthcare facilities perform periodic inspections of fire, smoke and.
Warning note on alarm systems or smoke control systems if any wiring to an alarm or smoke control has been touched, the fire marshal may require verification that the system remains functional. This memorandum permits hospitals to apply the nfpa 6year testing interval for fire and smoke dampers in hospital heating and ventilating systems, so long as the hospitals testing system conforms to the testing requirements under the. Fire dampers are installed to prevent the spread of fire where air ducts pass through fire resistant barriers. It is essential therefore that they are subject to regular inspection and fire damper testing. A fire damper can be defined as a device installed in ducts and air transfer opening of an air distribution or smoke control system designed to close automatically upon detection of heat. Smoke damper testing national fire protection association. Testing and inspection requirements for fire dampers confires. The benefits of integrated fire protection and life safety. Vss staff are independently trained to carry out fire damper testing. Amca nsw fire and smoke damper installation and certification. In the us, astm e2912 cover testing, combined with e119 where required. The software for automatic testing resides in the smokecontrol system. Fire dampers, smoke dampers, combination firesmoke dampers, ceiling radiation dampers and any other type of damper that performs a safety function in buildings fire protection or lifesafety system must work properly at the appropriate time during a fire or smoke emergency.
A fire damper is a piece of equipment that is designed to stop a fire from moving through ducting and spreading to other parts of a building. Apr 04, 20 how often should fire dampers be tested. Besides the damper test required by nfpa 105, nfpa 72 requires an annual test of the spottype smoke detector or duct detector that activates the smoke damper. Nfpa 72 9 is referenced when any smoke detection is present. Fire damper testing we can provide an essential fire safety service whereby all your fire dampers will be located to ensure they are within the fire containment area and that they can be fully accessed. Guide for facility managers on the testing and maintenance of fire dampers posted in testpage by ruskin co. Bsbsmb401a establish legal and risk management requirements. Visual inspections of smoke dampers as outlined in nfpa 105 are similar to the process for fire dampers. Fire damper testing and inspection bs9999 breathe vss. An integrated fire protection and life safety system combines the various individual systems that make up a buildings overall life safety approach. Important new besa guidance on fire damper testing.